Daniel Hilst e20f5fb621 fix(xcat-core): an aarch64 node writes its console to ttyS0, which does not exist
nodehm.serialport holds a port number, so the plugin that writes the kernel
command line also names the device. anaconda.pm, debian.pm, sles.pm, destiny.pm
and mknb.pm each chose between hvc for POWER and ttyS for everything else. An
aarch64 platform presents a PL011 serial port, which Linux names ttyAMA, so an
aarch64 node was told console=ttyS0 and wrote its console to a device that is
not there. A provisioning failure on such a node leaves no console record.

Three of those sites named ttyS with no architecture test at all, so a ppc64le
node lost its console the same way in mksysclone.

The device is now chosen in one place, xCAT::ConsolePolicy, which maps the
architecture to hvc, ttysclp, ttyAMA or ttyS and builds the console arguments
from a port and an optional speed. The ten call sites call it.
_genesis_uses_power_console is removed; destiny.pm calls the module.

console_policy.t covers every architecture and the empty-port case.
anaconda_console_device.t drives mknetboot and reads the arguments out of the
command line the plugin wrote: it fails on the unfixed tree with ttyS0,115200
where ttyAMA0,115200 is expected, and the ppc64le and x86_64 cases pass either
way, so a change that renamed every device would not satisfy it.

An aarch64 platform with a 16550 instead of a PL011 is not covered, as a POWER
machine without a hypervisor console is not: the map takes one device per
architecture, which is what the two existing entries already assumed.

Signed-off-by: Daniel Hilst <392820+dhilst@users.noreply.github.com>
(cherry picked from commit 1b984211212a12cd56603bdfb6fab6cecf197314)
2026-11-03 19:39:22 -03:00

69 lines
2.9 KiB
Perl

#!/usr/bin/env perl
#
# The console device each architecture is given, and the kernel arguments built from it.
#
# nodehm.serialport holds a port NUMBER, so the plugin that writes the kernel command line also
# names the device. Five plugins each chose between hvc and ttyS, so an aarch64 node was given
# console=ttyS0 while the platform presents pl011, which Linux names ttyAMA0.
use strict;
use warnings;
use FindBin;
use lib "$FindBin::Bin/../../perl-xCAT";
use Test::More;
use xCAT::ConsolePolicy qw(console_device_name kernel_console_arguments);
# SBSA requires a PL011 serial port, and that is what the aarch64 qemu virt machine presents.
is( console_device_name('aarch64'), 'ttyAMA', 'aarch64 uses the pl011 console' );
is( console_device_name('arm64'), 'ttyAMA', 'the Debian spelling of aarch64 uses it too' );
# A POWER machine presents both the physical and the virtual port as a hypervisor console.
is( console_device_name('ppc64le'), 'hvc', 'ppc64le uses the hypervisor console' );
is( console_device_name('ppc64el'), 'hvc', 'the Debian spelling of ppc64le uses it too' );
is( console_device_name('ppc64'), 'hvc', 'big-endian ppc64 uses it as well' );
is( console_device_name('s390x'), 'ttysclp', 's390x uses the service-call console' );
# A 16550 at a numbered port is what the remaining architectures present.
is( console_device_name('x86_64'), 'ttyS', 'x86_64 uses the 16550 console' );
is( console_device_name('riscv64'), 'ttyS', 'riscv64 uses the 16550 console' );
is( console_device_name('i386'), 'ttyS', 'i386 uses the 16550 console' );
# An unset arch must still name a device, because the caller interpolates the result.
is( console_device_name(undef), 'ttyS', 'an unset architecture falls back to the 16550 console' );
is( console_device_name(''), 'ttyS', 'and so does an empty one' );
is(
kernel_console_arguments( 'aarch64', '0', '115200' ),
'console=tty0 console=ttyAMA0,115200',
'an aarch64 node keeps tty0 and takes the pl011 port at its speed',
);
is(
kernel_console_arguments( 'ppc64le', '1', '19200' ),
'console=tty0 console=hvc1,19200',
'the port number and the speed are the ones the node was given',
);
# Genesis takes no speed on this path, so the comma must not be written either.
is(
kernel_console_arguments( 'aarch64', '0' ),
'console=tty0 console=ttyAMA0',
'an omitted speed leaves no trailing comma',
);
# nodehm.serialport unset is how a node says it has no serial console. The callers append the
# flow-control suffix to whatever comes back, so an empty string is the only safe answer.
is( kernel_console_arguments( 'aarch64', undef, '115200' ), '', 'no port means no console argument' );
is( kernel_console_arguments( 'aarch64', '', '115200' ), '', 'and an empty port means the same' );
# Port 0 is the first port, not a missing one.
is(
kernel_console_arguments( 'x86_64', 0, 115200 ),
'console=tty0 console=ttyS0,115200',
'port 0 is a port',
);
done_testing();