2
0
mirror of https://github.com/xcat2/xcat-core.git synced 2026-09-05 04:27:55 +00:00
Commit Graph

27609 Commits

Author SHA1 Message Date
Vinícius Ferrão e66a014564 test(dhcp): cover fabric identity compatibility 2026-08-26 22:23:02 -03:00
Vinícius Ferrão e392621593 fix(dhcp): align fabric identity handling 2026-08-26 22:23:01 -03:00
Vinícius Ferrão 1be564aef7 test(dhcp): preserve adjacent static hosts 2026-08-26 22:23:01 -03:00
Vinícius Ferrão 498240ea26 fix(dhcp): keep static host markers standalone
Keep the end marker on its own line so deleting one generated host cannot consume the declaration that follows it.
2026-08-26 22:23:01 -03:00
Vinícius Ferrão c045dd3ed3 test(dhcp): pin the InfiniBand identity of a node that boots over IPoIB
Drive the routine that makes the InfiniBand address and make sure that it
gives the port GUID of the two adapters that this was validated with, and that
it gives nothing for an address that is not a six byte ethernet mac.

Pin that the second entry waits for an ethernet node whose network an IPoIB
interface serves, that it carries hardware type 32 and the derived address,
that it does not take the place of the entry of the node, and that removing
the node removes it by name and by address.
2026-08-26 22:22:31 -03:00
Vinícius Ferrão 1e5de1e476 fix(dhcp): register the InfiniBand identity of a node that boots over IPoIB
A node that discovery finds over ethernet is known by its ethernet mac. When
that node boots over IPoIB, the request carries the InfiniBand identity of the
adapter and not the ethernet mac. dhcpd finds no host entry for that identity
and answers nothing, thus the node does not boot and the log gives no reason.

dhcp.pm already gives hardware type 32 to a node whose mac attribute holds an
8 or 9 byte fabric address, but that needs the fabric address before the node
boots, and discovery records the ethernet mac.

A Mellanox adapter makes its port GUID from the ethernet mac, by the insertion
of 03:00 in the middle. Thus the InfiniBand identity of the node is already
known. Write it as a second host entry with the -xcat-ib suffix and hardware type
32, so a request over either fabric finds the node and
receives the same address. Remove that entry with the node.

Write the second entry only for a node whose network an IPoIB interface
serves. A cluster with no InfiniBand keeps the host entries that it has today.

This is for the ISC backend. makedhcp returns into the Kea code before this
routine when Kea is the backend, and a Kea server does not answer an IPoIB
client, thus there is nothing there for a second entry to answer.

Recovered from the lenovobuild branch. Reimplemented against master: the
original writes the second entry for every ethernet node, which makes two
host entries for each node of a cluster that has no InfiniBand.
2026-08-26 22:22:31 -03:00
Vinícius Ferrão b2ad18137b Merge pull request #7766 from VersatusHPC/refactor/routeop-helper-reuse
refactor(routeop): reuse route classification helpers
2026-08-26 11:11:44 -03:00
Daniel Hilst b4c7936cc6 Merge pull request #7764 from VersatusHPC/refactor/dhcp-shared-os-version-parsing
refactor(dhcp): reuse shared OS version parsing
2026-08-26 11:09:02 -03:00
Daniel Hilst e8b0620345 Merge pull request #7757 from VersatusHPC/refactor/template-shared-ubuntu-version-comparison
refactor(template): use shared Ubuntu version comparison
2026-08-26 11:06:31 -03:00
Vinícius Ferrão 2dc4afd903 Merge pull request #7741 from stanford-rc/genpdu
feat: add `genpdu` pdutype for generic SNMP PDUs (PDU2-MIB)
2026-08-26 00:14:25 -03:00
Kilian Cavalotti 0b4695eef2 Accept MIB labels for genpdu enumerated values
With PDU2-MIB loaded, SNMP.pm returns an enumerated INTEGER as its label
rather than its number: a PX4 answers inletSensorUnits with "amp" rather
than "2". That failed the numeric test, fell back to none(-1) and
dropped the unit suffix from every rvitals reading.

Add pdu2_enum, which accepts the number, the label, or the label(value)
form Net-SNMP produces with quick printing off, and use it for the
sensor units and for outletSwitchingState.

Also stop requiring the switching probe to read on or off. An outlet can
be in any SensorStateEnumeration state, and pdu2_get has already ruled
out an absent instance, so any answer proves the outlet is switchable.

Signed-off-by: Kilian Cavalotti <kilian@stanford.edu>
2026-08-25 17:44:23 -07:00
Daniel Hilst ab7813e3e6 Merge pull request #7746 from VersatusHPC/fix/blade-findme-chassis-filter
fix(blade): let a discovery request reach the findme handler
2026-08-25 20:26:47 -03:00
Daniel Hilst 9a851988b8 Merge pull request #7745 from VersatusHPC/fix/rspconfig-per-bmc-args
fix(rspconfig): accept one network value per BMC
2026-08-25 20:21:31 -03:00
Vinícius Ferrão 763c90c116 test(discovery): cover shared findme decisions 2026-08-25 19:46:04 -03:00
Vinícius Ferrão b1ef0620de refactor(discovery): share blade findme decisions 2026-08-25 19:46:04 -03:00
Vinícius Ferrão 875f7d764d test(discovery): prepare shared findme helper loading 2026-08-25 19:33:08 -03:00
Vinícius Ferrão 6752cc9ce2 test(rspconfig): call the per-BMC helper directly 2026-08-25 18:47:11 -03:00
Vinícius Ferrão 0a8281880d test(blade): call the findme helpers directly 2026-08-25 18:47:10 -03:00
Vinícius Ferrão e4a912db10 refactor(rspconfig): isolate per-BMC setting selection 2026-08-25 18:47:10 -03:00
Vinícius Ferrão d6eca6f052 refactor(blade): isolate findme decisions 2026-08-25 18:40:56 -03:00
Vinícius Ferrão e10620c02f test(rspconfig): prepare direct helper loading 2026-08-25 18:40:56 -03:00
Vinícius Ferrão 07e591424f test(blade): prepare direct helper loading 2026-08-25 18:40:56 -03:00
Vinícius Ferrão d4c3191b07 docs(rspconfig): describe one network value per BMC
Record that a node with more than one BMC is configured one BMC at a
time and that a comma separated value gives one setting per BMC, in
both the man page source and the checked-in text.
2026-08-25 18:40:56 -03:00
Vinícius Ferrão 777fcfe561 test(blade): pin that a discovery request reaches the handler
Add a unit test for the entry decision of the blade preprocessor. The test
lifts the entry out of the plugin source and drives it, because the plugin
needs a management node to load in full.

The test gives the entry the request that a booting node sends, which names
no node, and shows that the entry hands it on and answers no error. It also
shows that a request for another command without a noderange is still
refused.
2026-08-25 18:40:56 -03:00
Vinícius Ferrão 8a64b224a3 test(rspconfig): cover one network value per BMC
Extract per_bmc_argument and the set of settings that take a list from
ipmi.pm, and drive the real routine, because the plugin needs daemon
dependencies that the test host does not have.

Cover a single value serving every BMC, a list read in session order, a
list too short for the BMC being configured, empty entries, and the
defensive inputs. Assert that only ip, netmask and gateway read a list,
that the caller reports a short list rather than sending it, that the
session keeps the value of its own BMC for the follow-up, and that the
thermal profile keeps its own argument.
2026-08-25 18:40:56 -03:00
Vinícius Ferrão 2d1f64f0fb fix(blade): let a discovery request reach the findme handler
A node that boots sends a findme request to say that it is there. That
request names no node, because the node is what the request asks xCAT to
find. The preprocessor of the blade plugin asks for a noderange for every
command, so it answers "Missing Noderange" with an error code and gives back
no request. The daemon then has nothing to give to the handler, and the
findme handler of the plugin does not run.

The plugin therefore answers each discovery request with an error, and blade
discovery does not happen. The check that asks for a noderange is older than
the findme handler.

Hand a findme request to the handler, as the switch plugin does for the
commands that it does not preprocess. Every other command keeps the check.

The preprocessor also held a test that removed a node from a findme request
when the hardware type was not blade. A findme request now returns above that
test, and it named a noderange that a findme request never carries, so the
test could not run. Remove it.
2026-08-25 18:40:56 -03:00
Vinícius Ferrão cbf5cb3dae test(blade): pin which rows of the mp table are blades
Add a unit test for the routine that selects the blades. The test lifts the
routine out of the plugin source, because the plugin needs a management node
to load.

The test gives the routine the row shapes that the writers of the mp table
make: a management module and its blades from xCAT::PPCdb::add_systemX and
the shipped mp template, a chassis that gives its hardware type, and one row
for each hardware type that lsslp writes. It also shows that the handler
reads the chassis attribute and that it stops before the arp table when the
mp table holds no blades.
2026-08-25 18:40:56 -03:00
Vinícius Ferrão f9ed90ec0b fix(rspconfig): accept one network value per BMC
A node can carry more than one BMC, and rspconfig already opens a
session per BMC for rinv, reventlog, rvitals and rspconfig. A setting
such as ip= carried a single value, so every BMC of the node received
the same one. Two BMCs cannot share an address, so a node like that
could not be configured through rspconfig at all.

Read a comma separated value as one setting per BMC, in the order the
sessions are numbered. Only the ip, netmask and gateway settings read a
list, because a comma belongs to the value itself in a free form SNMP
community string. A value without a comma still reaches every BMC, so
the existing single BMC use is unchanged.

An entry that is missing or empty reports the mismatch instead of
reaching the address encoders, which reject an empty string. The
session then holds the value of its own BMC, because the follow-up
callbacks read the subcommand again to decide whether the address came
from DHCP.

Recovered from the lenovobuild branch.
2026-08-25 18:40:55 -03:00
Vinícius Ferrão 097554ba34 fix(blade): ask only the blades of a chassis for a discovery inventory
The findme handler of the blade plugin makes an inventory request for each
node in the mp table. That table holds more than the blades of a chassis.
lsslp writes a row for a Power BMC, for an FSP, for a BPA, for an HMC and for
other hardware, and xCAT::PPCdb::add_systemX writes a row for a management
module. None of that hardware answers a blade inventory.

Keep a row that gives blade as its hardware type. Keep also a row that gives
no hardware type but names a different node as its mpa, when that other node
is a management module. The mp template in xCAT/templates/e1350 leaves the
hardware type of a blade empty, so a test of the hardware type alone loses
the blades of a chassis.

Return when the table holds no blades. The work below the filter reads the
arp table of the management node, and a site that has no chassis must not pay
for that on each discovery request.

Recovered from the lenovobuild branch, which tested the hardware type only.
2026-08-25 18:40:55 -03:00
Vinícius Ferrão 593e349557 Merge pull request #7769 from VersatusHPC/feat/genesis-common-repository
feat(genesis): consume packaged OpenEmbedded images
2026-08-25 12:42:16 -03:00
Vinícius Ferrão 8fadd0664e test(genesis): cover reviewed edge cases
Signed-off-by: Vinícius Ferrão <2031761+viniciusferrao@users.noreply.github.com>
2026-08-25 11:27:13 -03:00
Vinícius Ferrão 8e94cd157a fix(genesis): complete artifact cleanup
Signed-off-by: Vinícius Ferrão <2031761+viniciusferrao@users.noreply.github.com>
2026-08-25 11:26:47 -03:00
Vinícius Ferrão 114faaae85 test(genesis): load plugin from library path
Signed-off-by: Vinícius Ferrão <2031761+viniciusferrao@users.noreply.github.com>
2026-08-25 11:26:47 -03:00
Vinícius Ferrão 9edbbc1817 test(genesis): use explicit fractional sleep
Signed-off-by: Vinícius Ferrão <2031761+viniciusferrao@users.noreply.github.com>
2026-08-25 11:26:47 -03:00
Vinícius Ferrão a983faf736 fix(genesis): retire stale legacy initramfs
Signed-off-by: Vinícius Ferrão <2031761+viniciusferrao@users.noreply.github.com>
2026-08-25 11:26:47 -03:00
Vinícius Ferrão 200302ca03 test(genesis): cover stale initramfs selection
Signed-off-by: Vinícius Ferrão <2031761+viniciusferrao@users.noreply.github.com>
2026-08-25 11:26:47 -03:00
Vinícius Ferrão 72a0cc9b58 docs(genesis): make offline mirrors verifiable 2026-08-25 11:26:46 -03:00
Vinícius Ferrão 33124a1483 fix(genesis): preserve canonical ppc64 images 2026-08-25 11:26:46 -03:00
Vinícius Ferrão ecce32a3d6 test(genesis): cover offline repository gaps 2026-08-25 11:26:46 -03:00
Vinícius Ferrão 2c5351683d docs(genesis): fix offline repository setup 2026-08-25 11:26:46 -03:00
Vinícius Ferrão ca1b0cbd67 fix(genesis): protect Power architecture fallback 2026-08-25 11:26:46 -03:00
Vinícius Ferrão 14c45107d0 test(genesis): cover final review gaps 2026-08-25 11:26:46 -03:00
Vinícius Ferrão dbda52f3da docs(genesis): complete repository handoff 2026-08-25 11:26:46 -03:00
Vinícius Ferrão 719e5aecab fix(genesis): close consumer review gaps 2026-08-25 11:26:46 -03:00
Vinícius Ferrão f853d52b98 test(genesis): cover release review gaps 2026-08-25 11:26:45 -03:00
Vinícius Ferrão ba2c1e75bc fix(genesis): finish consumer integration 2026-08-25 11:26:45 -03:00
Vinícius Ferrão d43bda0005 test(genesis): cover final consumer gaps 2026-08-25 11:26:45 -03:00
Vinícius Ferrão f5d1bd8e73 fix(genesis): complete boot consumer wiring 2026-08-25 11:26:45 -03:00
Vinícius Ferrão 3fa8446d08 test(genesis): cover boot consumer gaps 2026-08-25 11:26:45 -03:00
Vinícius Ferrão 52b0a0aedd test(genesis): mark sourced script fallback 2026-08-25 11:26:45 -03:00