A read only ever looked at the manager's log services, and fell back to the
system's when the manager published none. A platform that keeps an event log
in both places had the second one invisible: an AMI MegaRAC keeps power unit
and thermal events in a chassis log that nothing read, 103 records that no
command could reach.
Clearing deliberately does not follow. It stays where it was, so a log that
only a read reaches is never destroyed by one, and clearing a platform that
keeps its only event log on the system still works.
The name test now ignores spacing, since a build that calls its post code log
"BIOS POST Code Log" was read as an event log and merged 2719 post codes in.
Reading an event log skipped every log service whose id or name said journal,
dump, post code, host logger or crash, on every implementation. Those names
are bmcweb's: the AMI and Lenovo bmcs call theirs SEL, EventLog, AuditLog and
PlatformLog. bmcweb does need the distinction, keeping its event log under the
system while a clear would destroy its dumps, so it gets a handler that names
the words and generic names none, reading whatever a platform publishes.
Generic added an UpdateParameters part to every multipart firmware push,
because the specification has one carried. Only the AMI firmware was seen to
insist on it, so name it in that handler and let generic send what the caller
passed.
A bmc behind a forward answers Activate Payload with the port it listens on
itself, and the advertised-port check refused that, so a console failed where
command traffic worked. The advertised port is never sent to, so the check now
applies only on the default port. A bmc on another port advertising a third one
is no longer refused outright, which nothing here could have served anyway.
The plugin connected to 623 whatever the address said, with a TODO in place of
the parsing. It now reads one as the redfish plugin does, minus the brackets,
which getaddrinfo rejects.
IpmiConsole keys its endpoint mapping on host and port so several bmcs behind
one address stay distinct, and unregisters only an entry it actually claimed.
_unixdomainhandler hardcoded /var/run/confluent/api.sock in four places and
derived its directory from a fifth. It is now threaded through SockApi like
the other bind settings, defaulting to the same path. That lets a service run
on a temp socket as an ordinary user, which is what a test needs.
The deadline was set when monitoring began, so a flash that kept
answering for longer than the grace period had already spent it by the
time the reboot it covers arrived, and reported a working update as a
failure.
A device holds its sensor records per lun and scopes the reservation the
same way, so a token taken on lun 0 can be refused for lun 1 with 0xc5.
The retry then took the same wrong token again without end.
Firmware for a supply or a fan matched no fragment and so was called
core, and nothing could ever answer for misc.
Only the collections that mean one thing are matched by url. A Storage
resource is the subsystem, so its firmware is the controller rather than
a drive, and a Processor is a cpu as readily as an accelerator, so that
one is decided by asking the processor what it is.
A member of a collective that cannot reach quorum stalls in the startup loop
until quorum returns, and there was nothing in that loop that noticed a
shutdown. That was survivable while SIGTERM raised SystemExit out of the
signal handler, since that escaped the loop from wherever it happened to be.
Having the event loop deliver the signal instead leaves the stop event set with
nobody reading it until quorum is reached, so stopping the service waits out
the systemd timeout and ends in a kill.
Check the event in the loop condition, and wait on it rather than sleeping
through it, so the answer comes in milliseconds rather than whenever quorum
returns. A service stopped at this point has served nothing yet, so it goes
straight to the same configuration flush the normal exit does.
pyghmi asks for this parameter with xraw_command and catches the completion
code for a bmc that does not have it, and folding aiohmi in renamed that call
to oldraw_command rather than raw_command, so the handler could no longer fire.
Answering the code out of the returned dictionary repaired the crash but kept
the call on the older contract, which is now the only one left in the tree.
Catch it again instead: raw_command puts the completion code on the exception
as ipmicode, and nothing here reads the payload of a reply that carries a code,
which is the one thing catching gives up.
No behaviour change, checked against the previous version over the same fake
session for a good reply, an empty one, 0x80 and 0xC9 with and without a stray
payload, four other completion codes, a timeout, a lost session and a reply
with no data at all: same return value, same exception type, text and ipmicode,
same bytes on the wire.
_read_device_sdr_lun negotiates the read size down when the bmc answers 0xCA,
but the size > 5 guard leaves a size of 5 alone, so a bmc that will not serve
5 bytes at once was asked the same question for ever. Give up once the
request cannot get any smaller, and once a header read would go under the 5
bytes the record length sits in, by falling through to the raise already
there.
The stale reservation retry could not end on its own either: it cleared the
id and left taking a new one to the top of the loop, which only reserves for
a partial read, so the very first request repeated unchanged. Take one where
the code is handled.
Completion codes 201 and 202 mean the chunk asked for was too big, and the
check for them sat after a call that raises, so a bmc that cannot serve 224
bytes at once failed the fru read rather than being asked for less.
The retry could not terminate either: chunksize // 2 + 2 is 4 for a chunksize
of 4, so the chunksize == 3 guard was unreachable and a bmc that kept refusing
would have been asked for 4 bytes for ever.
Completion code 203 on a sensor reading means the sensor is not present, which
is expected of an optional device, but the check for it sat after a call that
raises first, so one absent sensor ended the whole sensor sweep.
_supports_standard_ipv6 read rsp['code'] the same way, so it could only ever
answer True; a platform without the standard parameters raised instead. A
completion code is that platform's answer, while a timeout or a lost session is
not and must not be cached as one.
raw_command's docstring still described itself as the other call it was renamed
from, which is how these checks came to be written against the wrong contract.
raw_command raises on any nonzero completion code, so the 0xCA and 0xC5 checks
in get_sdr could not run: a bmc that will not return a whole record in one go,
or whose reservation went stale, failed the sensor load outright instead of
being retried. Read the code from the exception, which carries it.
The back off also had a fixed point, size // 2 + 2 being 3 for a size of 3, so
a bmc that kept refusing would have been asked the same question for ever.
Give up when the request cannot get any smaller. A header read cannot go
under 5 bytes either, since that is where the record length sits, so give up
there rather than parse a reply too short to index.
The stale reservation retry could not end on its own either: it cleared the id
and left taking a new one to the top of the loop, which only reserves for a
partial read. Take one where the code is handled.
The labels are worked out across the whole inventory, since a platform may give
every entry the same Name, so an entry that came back empty would be asked for a
name it does not have and take the naming of the others with it.
A parameter file that is not json, or that holds something other than an
object, reached the update as a raw parser message or as a TypeError from the
handler that unpacked it.
A writable directory only says the user could have created a file there, and
/tmp lets anyone do that. If the target exists, it has to be writable by the
requesting user too, or confluent would overwrite it as root.
get_user_name documents that it answers None when reading a slot fails, but
raw_command raises before the check that would return it, so that branch has
never run and one refused slot aborted the whole user list. Answer None where
the docstring says to, and let get_users drop the blanket except it grew to
work around it.
Only a completion code counts as the bmc answering about the slot. A timeout
carries the fabricated 0xffff from the session layer and a lost session carries
no code at all, and swallowing either of those reports a list truncated at the
point of failure as a complete one.
Some will not take an image without being told which kind it is, and the
only way to find out was to attempt an update and read the error, which
writes to the bmc before it gets that far.
The sdr carries unit fields for every sensor record, and they were read into
the reading whether or not the sensor has a number for them to describe. A
discrete sensor reports which of its states are asserted and no value at all,
so a watchdog came back with units of "% ", and a discrete sensor on a full
record picks up a base unit the same way, reporting degrees celsius for a
sensor that never has a temperature. A caller that shows the unit alongside
whatever value it was handed then prints a unit with nothing to apply it to,
which is what the client was taught to skip in 8c8c32cc. The client is not
the only consumer of a reading, so answer the question in the library.
The record itself says which sensors those are, and the reading path already
works it out to decide whether to decode a number: a sensor has one only if
the numeric format says how to read it, or the format is unsigned and the
record either supports thresholds or is of reading type 1. Ask that once,
where the units are assembled, and give the sensors that fail it no unit, so
the unit and the value cannot come to different conclusions about whether the
sensor has a reading at all.
A threshold or numeric sensor reports exactly what it did before, including
the ones whose unit is a percentage, a combination of two units, or nothing
because the record names no unit. On the Lenovo XCC this was checked against
nothing changes: its 305 readable sensors decode identically, discrete ones
included, because they are all compact records naming no unit in the first
place. The sensors that change are the ones the finding came from, which
name a unit on a record that has no number to put it on.
A path a caller wants confluent to save something into was being run through
the check meant for a file confluent is asked to read. That check forks, drops
to the calling user and asks os.access for R_OK, which is false for every file
that does not exist yet, so nodesupport servicedata and save_licenses could
only be given a path that was already there. Handed a name to create, they
refused, and refused in a way no caller was looking for, so the command printed
nothing and exited zero.
The previous commit worked around it by skipping the check for a download
target, which fixed the symptom by removing the guard rather than by asking the
right question. Ask the right question instead: whether the user could have
created the file in that directory themselves. A path that is already a
directory is a destination directory, anything else names the file, which is
the same rule the code that goes on to write the file follows.
So a caller can still only make confluent write where they could have written,
and this now also catches an unwritable destination at the point the request is
made rather than several layers further in.
This bmc gives all three of its firmware entries the same Name, "Software
Inventory", and puts what they actually are in the description. The first
entry took that name, and the two after it fell back to their ids, so
nodefirmware answered with "Software Inventory", "cpld_active" and
"d1dc9e4b" for what are the host, cpld and bmc images.
Decide the labels across the collection rather than one entry at a time,
so a name the platform repeats can be recognised as no name at all. Where
that happens, use a description that does tell them apart, and the id when
even that is shared. A platform whose names are already distinct keeps
exactly the names it had.
The labels are what a caller addresses an entry by, so this also turns
inventory/firmware/all/d1dc9e4b into inventory/firmware/all/bmc_image.
Processor inventory carried a single field, the model, so a platform that
does not give one had a processor in the listing with nothing in it, and
the client, which skips empty values, showed no processor at all. This
bmc names the manufacturer, the socket and the core and thread counts, and
gives no model.
Carry those, along with the speed, serial and part number where a platform
offers them, and treat a processor as missing only when the bmc says its
state is absent, rather than whenever it does not describe a state.
The top bit of the major revision byte of Get Device ID says the device is
still initialising or taking a firmware update. It was read as part of
the revision, so immediately after a bmc reset nodefirmware reported "BMC
Version: 131.11" for what is 3.11, and settled down only once the bit
cleared.
Mask it as sdr.py already does for the same byte, so the two agree about
the same field.
Reading the identify state says plainly when a platform describes no
indicator, but writing it went ahead and patched IndicatorLED regardless.
This bmc has neither that property nor the boolean that replaced it, and
answered the write with an internal service error, which reached the user
as one and the log as a traceback.
Ask the same question the read asks. With neither property present there
is nothing to write, so say so in the same words instead of finding out
from the bmc.
This bmc advertises a Bios resource on its system and answers 404 for it.
Confluent followed the link and passed the bmc's complaint on as an
unexpected error, so a nodeconfig read printed every bmc setting and then
ended with "The requested resource of type named 'Bios' was not found",
and the system half of the configuration was a 500 saying the same.
There is already a good answer for a system that offers no bios settings,
and a link that is advertised and not served is the same thing as far as a
caller is concerned, so give it the same one. The result is checked once
and remembered, including the negative, so this costs one request on the
first ask and nothing after.
Redfish identifies an account by a string, and an implementation is free
to use the account name, which this one does. The handler converted the
last element of the path to an integer, so every per user read, update and
delete answered "invalid literal for int() with base 10: 'root'" as an
unexpected error, with a traceback to match. Confluent offered the id
itself, listing the account as "root", and then could not accept it back.
Take the element as given. Everything below already compares ids as
strings, and the input parsing already keeps a non numeric uid, so only
this conversion stood in the way. nodebmcpassword goes through exactly
this path, reading users/all for the id and then writing to that account,
so it could not work at all on such a bmc.
ipmi users really are numbered slots, so the conversion is right there and
stays, but say so when it fails rather than letting a ValueError surface
as an unexpected error.
A caller asking for fans or energy got nothing from any bmc that serves
the Sensors collection. Those sensors were filed under their redfish
reading type, Rotational for a fan, while the categories are named after
the ipmi sensor types the rest of the code uses, so nothing matched.
Power appeared to work only by coincidence, Power and Current happening to
be spelled the same in both vocabularies.
Translate the reading type as the sensor is mapped, so a sensor means the
same thing whether it came from the Sensors collection, from the older
Thermal and Power documents, or from ipmi. On the bmc this was found on,
fans go from nothing to the 24 tachometers, and temperature and power
already agreed with what the same hardware reports over ipmi.
The fan controls stay out, and cannot be brought in. Their reading type
is Percent, which is also what a battery state of health reports, and this
bmc fills in no PhysicalContext to tell them apart, so there is nothing to
classify them by that would not also drag in unrelated percentages.
The loop decoded the first three bytes of a name and never consumed them,
so any sensor or fru name a bmc encodes as 6 bit packed ascii spins at
full speed, appending the same four characters until the process runs out
of memory. Measured at about 10 MB a second, so a bmc using an encoding
the spec gives its own worked example of costs a pinned core and, before
long, the daemon.
Consume each group, and decode a trailing group of one or two bytes rather
than dropping it, since those carry a character each and the name would
otherwise come back short.
The arithmetic was already right, it was only never reached a second time.
Verified by encoding names per the packing and reading them back: exact for
every length except those leaving three characters in a three byte group,
where the byte count cannot say whether three or four were meant and a
trailing space is unavoidable.