Boot URLs handed to nodes always carried an explicit :80 even when the HTTP
server listens on the default port. grub2.pm already omits the port when it is
80; make the xNBA, genesis and DHCP boot URLs consistent with it.
$portsuffix is empty when site.httpport is unset or 80 and ":<port>" otherwise,
so a non-default port is unchanged. Covers the ISC and Kea paths in dhcp.pm,
xnba.pm, mknb.pm, and the Kea xNBA client classes in BootPolicy.pm.
dhcp_boot_policy.t and mknb_xcatd_address.t follow the new URLs and gain cases
for a non-default and an unset port. The floating-address guard in
mknb_xcatd_address.t also drops :80 so that it keeps matching.
Recovered from the unmerged lenovobuild branch (cd61fd9d, a2f77ea9, 1035841b,
b7db0e2, 792fe6d).
Co-authored-by: Jarrod Johnson <10814490+jjohnson42@users.noreply.github.com>
When invoked with no node name, replaycons printed a terse "Please specify a
node name." Print the full usage statement instead, consistent with -h.
Also document, in the man page, that confluent log rotation renames older logs
and how to replay one by appending the date suffix seen in
/var/log/confluent/consoles/.
Recovered from the unmerged lenovobuild branch (originals 1c1b23fac, 48a92b7d4).
Co-authored-by: Jarrod Johnson <10814490+jjohnson42@users.noreply.github.com>
Running rspconfig against an mgt=ipmi node with no option fell through to the
generic "Unsupported command: rspconfig " message (with an empty option),
which does not tell the user what is wrong. Detect the empty option in
preprocess_request and report that options are required.
Recovered from the unmerged lenovobuild branch (original 08ae94bd).
Co-authored-by: Jarrod Johnson <10814490+jjohnson42@users.noreply.github.com>
nodestat -f runs fping to reach the nodes; if the fping package is not
installed the pipe yielded no output and nodestat silently returned an empty
result. Check that an fping binary exists before running it and emit an
explicit "must install fping" error otherwise.
Recovered from the unmerged lenovobuild branch (original f0c88182), reworked
to test for the binary directly: the original inferred fping's presence from
whether the pipe produced output, which false-positived (reporting fping
missing) when fping was present but every node was unresolvable -- caught in
lab validation.
Co-authored-by: Jarrod Johnson <10814490+jjohnson42@users.noreply.github.com>
The FRU key sort used only `$a <=> $b`, a numeric comparison that returns 0
for the non-numeric FRU field names, leaving them in hash-iteration order.
That order is randomized per process, so `rinv <node> all` printed its fields
in a different order on each run. Add `$a cmp $b` as a tiebreaker so the
output is stable.
Recovered from the unmerged lenovobuild branch (original 9cd3fac6).
Co-authored-by: Jarrod Johnson <10814490+jjohnson42@users.noreply.github.com>
systemd tooling run inside the image chroot has no bus to talk to and prints
"Failed to connect to bus: No such file or directory". The image builds
correctly, so say so at the end of the run instead of leaving it to be guessed.
Recovered from the unmerged lenovobuild branch (e372fb5b).
Co-authored-by: Jarrod Johnson <10814490+jjohnson42@users.noreply.github.com>
noderes.netboot is parsed as grub2-<protocol> and validated with
/^http|tftp$/, which reads as (^http)|(tftp$) and so also accepts values
such as https, httpx and xtftp.
A value that passes but is not exactly "http" then falls through to
set root=$grub2protocol,$serverip, which drops site.httpport, so the mistake
surfaces as a confusing grub2 failure at boot instead of the "Invalid netboot
method" error this check exists to give. grub2-https cannot work in any case,
since only "insmod http" is emitted.
Supported values are unchanged: grub2, grub2-http and grub2-tftp.
The SLE AutoYaST profile sized the root partition with <size>auto</size>, which
lets YaST pick a size and can leave the rest of the disk unused. RHEL
(part / --grow) and Ubuntu (root uses the remaining space) both give root the
whole disk; make SUSE consistent by using <size>max</size>. Swap stays auto.
Recovered from the unmerged lenovobuild branch (9a8679f4).
Co-authored-by: Jarrod Johnson <10814490+jjohnson42@users.noreply.github.com>
blade.pm's preprocess_request iterates the mp table during 'findme' discovery.
Because many node types populate the mp table, non-blade nodes were being
scanned as if they were BladeCenter/Flex blades. Skip a node during findme
unless its nodetype is 'blade'.
Scoped to blade.pm's findme path and gated on nodetype, so only blade discovery
is affected; the existing whole-request findme handling (already-processed
short-circuit) is a separate check and is unchanged.
Not lab-validated (no BladeCenter/Flex MPA available).
Recovered from the unmerged lenovobuild branch (6573d8f9).
reseat_node opens an IPMI session to the FPC/CMM to reseat a node. The FPC
needs packets sent without maxpending flow-control, but that state is only held
transiently. Add a persistent per-session 'neverwait' flag, set it on the FPC
reseat session, and honor it in sendpayload.
The flag defaults off, so it is a no-op for every other IPMI session; only the
FPC reseat path opts in. (The lenovobuild original also reworked the shared
login/admin_level_set nowait handling; that part is left out to avoid changing
flow-control for all BMCs.)
Not lab-validated (no NeXtScale FPC/CMM available).
Recovered from the unmerged lenovobuild branch (eda85df3, neverwait hunks only).
UEFI ESXi netboot needs esxboot-x64.efi under /xcat. When it was not
already staged, mkcommonboot left it missing; copy it from the install media's
efi/boot/bootx64.efi if that exists and the target does not.
Additive and ESXi-only (esx.pm mkcommonboot): it only copies when the target is
absent and the source is present. The original commit also dropped a
"bootmode ne install" guard whose own comment warns the installer croaks; that
hunk is intentionally left out.
Not lab-validated (no ESXi provisioning environment available).
Recovered from the unmerged lenovobuild branch (6931200d, esxboot hunk only).
On a node whose OS disk is an Intel RSTe/VROC software RAID (/dev/md/Volume0_0
or /dev/md/Volume0), disk auto-detection finds nothing and getinstdisk falls
back to the hard-coded /dev/sda. Prefer the VROC volume over that default.
Only fires when no install disk was otherwise selected and the VROC device
actually exists, so it cannot mis-select over a real disk and has no effect on
non-VROC systems. The original commit hooked into a lenovobuild-specific M.2
detection block absent from master; adapted to master's fallback point.
Not lab-validated (no VROC hardware available).
Recovered from the unmerged lenovobuild branch (c6c70e5).
The energy-manager (IEM) command handler treated response code 0xcb as the
'not present / not supported' signal. Some BMCs return 0xc1 for the same
condition, which was left unhandled. Accept 0xc1 as well.
Recovered from the unmerged lenovobuild branch (06d7097).
The rinv firmware-inventory path detects a Lenovo IMM by matching the firmware
build-ID prefix (yuoo, 1aoo, tcoo). Some IMM firmware families report a tei, cdi
or psi prefix and were therefore not recognized as an IMM. Add them.
Recovered from the unmerged lenovobuild branch (e50cf37, 201b2de).
Co-authored-by: Jarrod Johnson <10814490+jjohnson42@users.noreply.github.com>
ddns.pm's DNS-update send has a 3-try retry loop, but it only retried on
NOTAUTH and -- on the final attempt -- the `next` fell out of the loop without
reporting failure. makedns then printed "Completed updating DNS records." and
"DNS setup is completed" even when the update was never accepted.
Two problems this causes:
- SERVFAIL was never retried. named routinely replies SERVFAIL transiently
right after a zone (re)load, before the zone is ready to accept dynamic
updates; the update succeeds a second or two later. This reliably breaks real
flat-cluster provisioning on el9/el10, where the test case's makedns -n runs
right after named reloads the zone with the new compute node.
- A persistent NOTAUTH/SERVFAIL (retries exhausted) was silently swallowed and
reported as success, so a genuinely failed DNS update looked like it worked.
Extract the batch send into send_ddns_update(), which retries NOTAUTH and
SERVFAIL (pausing on SERVFAIL), returns 0 only on NOERROR, and otherwise emits
the error and returns 1. Both batch-send sites now `return 1 if
send_ddns_update(...)`, so a real failure aborts add_or_delete_records instead
of falsely reporting success.
Signed-off-by: Daniel Hilst <392820+dhilst@users.noreply.github.com>
Modern x86-64 UEFI firmware (including OVMF and recent iPXE) reports DHCP
client architecture 00:07, but the xNBA network-boot conditionals only matched
00:09. A UEFI node would load xnba.efi, re-request with user-class xNBA and
arch 00:07, fail to match, and be handed xnba.efi again -- an endless boot
loop. Accept 00:07 alongside 00:09 in the xNBA UEFI branches of both the
network-level (addnet) and node-level (addnode) dhcpd statements.
Validated on an OVMF UEFI client: it progresses from xnba.efi to the .uefi
genesis config and boots, instead of looping on xnba.efi.
Recovered from the unmerged lenovobuild branch (5d697b5c, 86b0e12e).
Co-authored-by: Jarrod Johnson <10814490+jjohnson42@users.noreply.github.com>
The generated /opt/xcat/xcatinstallpost ran the install postscripts first and
only disabled the xcatpostinit1 service afterwards. If one of those postscripts
rebooted the node (for example a firmware or kernel update), the service was
still enabled, so on the next boot the whole postscript set ran again from the
start. Disable the service *before* running the postscripts so a mid-postscript
reboot cannot re-trigger them.
The disable decision reads OSVER (base variant only), RUNBOOTSCRIPTS and
NODESTATUS, which the included xcatinstallpost script would otherwise set.
Moving the INCLUDE below the disable block leaves those variables unset, so read
them up front (the included script re-reads them) and source xcatlib.sh so
msgutil_r is available; the disable decision is then identical to before.
The original change (lenovobuild 9184cbe0) touched only the legacy post.xcat.
Modern EL uses the systemd variants: post.xcat.ng (RHEL/CentOS 8 and 9) and
post.xcat.rhels10 (RHEL 10). Apply the same reorder to all three so the fix
actually takes effect on current platforms.
Lab-validated with a full AlmaLinux 9.8 stateful install (post.xcat.ng path):
the generated xcatinstallpost disables the service before running the
postscripts, the postscripts run exactly once, the node reaches "booted", and
with the default NODESTATUS=1 the service is left enabled just as before.
Recovered from the unmerged lenovobuild branch (original 9184cbe0), adapted and
extended to the .ng and .rhels10 variants.
Co-authored-by: Jarrod Johnson <10814490+jjohnson42@users.noreply.github.com>