2
0
mirror of https://github.com/xcat2/confluent.git synced 2026-11-20 17:32:21 +00:00
Commit Graph

13 Commits

Author SHA1 Message Date
Markus Hilger 4aa6bf8af5 Accept plain device names in deployment.storage and fail on no match
The attribute help promises "a specific device name", but getinstalldisk
only understood "m2" and "/dev/<name>". A plain "nvme0n1" aborted the
install with "Unknown deployment.storage specification", and a
"/dev/<name>" that matched no disk was silently ignored, so the OS went
to whatever disk the default ordering picked. For an attribute meant to
pin the OS disk that is the dangerous failure mode.

Accept a kernel name with or without /dev/ and resolve /dev/disk/by-*
links to their kernel name, so a disk can be pinned by a stable path.
When nothing matches, fail with "No disks match" like the m2 filter
already does. Document the accepted forms in the attribute help.
2026-10-30 09:43:54 +01:00
Robert Caliman 1e57488f0d Add changes for 7mm disk without a RAID volume 2026-08-28 14:30:32 +03:00
Robert Caliman 84cf69ac4f Update string for 7mm to the correct form 2026-08-28 12:44:55 +03:00
Jarrod Johnson 48280ee5d3 Enhance VROC member criteria
Try to propogate form factor of member disk to array.

Also, even if cannot detect m.2, assume a two-member vroc array of nvme is m.2.  Not guaranteed, but most likely.  This is to deal with lack of DMI information indicating the physical form factor.
2026-08-27 16:55:18 -04:00
Jarrod Johnson 724818111c Merge pull request #283 from robertcaliman/rcaliman/add-more-m2-models
Add some more RAID models to the PRIORITY_MODELS
2026-08-27 15:49:45 -04:00
Robert Caliman 252b644f34 Remove the 16i models 2026-08-27 22:45:08 +03:00
Jarrod Johnson 34e7a10cfc Refer to self instead of non-existant disk 2026-08-27 15:43:17 -04:00
Jarrod Johnson 116d4aeb04 Make m.2 form factor drives a high priority as a matter of course for OS install 2026-08-27 15:41:49 -04:00
Robert Caliman 9c51577652 Add some more RAID models to the PRIORITY_MODELS 2026-08-27 22:39:56 +03:00
Jarrod Johnson 138b776c9c Recognize SATA m.2 drives
SATA drives do not directly have a busaddr.

However, at some point the PCI bus comes up in the udev hierarchy as a KERNELS value.

If that matches a detected M.2 slot, then accept the storage as M.2.
2026-08-20 12:03:09 -04:00
Jarrod Johnson d7dcb07a3f Implement deployment.storage
This is an attribute for a node to indicate preferences for storage.

For now, 'm2' policy will hit m.2 and mirroring kits.
2026-07-28 15:02:27 -04:00
Jarrod Johnson 53172f760f Have the priority models brought out and more documented 2026-07-14 08:30:34 -04:00
Jarrod Johnson 1042404a38 Move getinstalldisk for all the Linux into a common place
esxi is the only one with a different version