Reseat EUREKA nodes with the Reseat reset type

ForceRestart only restarts the host, so the node BMC kept running and
a reseat did not recover a hung one. The EUREKA firmware provides a
Reseat reset type that removes all power from the slot.
This commit is contained in:
Markus Hilger
2026-09-24 19:04:28 +02:00
parent 7cc8972170
commit 859a8db873
@@ -117,10 +117,12 @@ class OEMHandler(generic.OEMHandler):
return cputemps
async def reseat_bay(self, bay):
"""Power cycle a specific node in the EUREKA enclosure.
"""Reseat a specific node in the EUREKA enclosure.
Uses ComputerSystem.Reset with ForceRestart on the target node.
bay=-1 (enclosure-level) is not supported.
Uses ComputerSystem.Reset with the EUREKA specific Reseat type,
which removes all power from the slot, node BMC included.
ForceRestart only restarts the host. bay=-1 (enclosure-level)
is not supported.
"""
if bay == -1:
raise exc.UnsupportedFunctionality(
@@ -128,7 +130,7 @@ class OEMHandler(generic.OEMHandler):
nodeurl = '/redfish/v1/Systems/Node{}'.format(bay)
await self._do_web_request(
nodeurl + '/Actions/ComputerSystem.Reset',
{'ResetType': 'ForceRestart'},
{'ResetType': 'Reseat'},
method='POST')